Teltonika EVC2 CT Clamp
The Teltonika EVC2 CT clamp measures the total electrical load at the distribution board and supplies this information to the EVC2 charger for load-management functions. It is intended for installations where the distribution panel is close to the charger.
Fit one clamp around the individual phase conductor specified in the EVC2 installation instructions. The required number of clamps depends on the monitored supply configuration; follow the approved wiring diagram. The charger can then adjust charging power according to the configured load limit, helping to avoid overloading the electrical installation.
Technical data
- Primary current: 100 A
- Accuracy class: 0.5
- Operating frequency: 50 Hz ±10%
- Power consumption: 1.5 VA
- Operating temperature: -25 to +55 °C
- Dimensions: 85 × 45 × 90 mm; weight: 300 g
- Flame-resistant PC housing, black
Installation
Keep the cable distance between the CT clamp and the EV charger within 15 m for best accuracy. Installation must be carried out by a qualified electrician in accordance with the charger instructions and local electrical regulations.
Package contents
Package contains: EVC2 CT clamp.
| Environmental conditions | |
| Operation temperature | -25°C - +55°C |
| Storage temperature | -30°C- +70°C |
| Relative humidity | ≤ 75% |
| Electrical specification | |
| Primary current | 100A |
| Operational frequency range | 50Hz ±10% |
| Accuracy class | 0.5 |
| Power consumption | 1,5VA |
| Mechanical and enclosure specification | |
| Product dimension (outline) | 85mm(W) x 45mm(D) x 90mm(H) |
| Enclosure material | PC flame resistant plastic |
| Enclosure colour | Black |
| Product weight | 300 g (net) |
Tags: Teltonika EVC2 CT clamp, 100 A current transformer, EV load management, charging accessory